CONTINGENCY PLAN FOR FIRE AND EXPLOSION

0
General emergency alarm signal : Seven or more short blast followed by one long blast Emergency:- Immediate Action Required/Members of The Team Fire and Explosion:- Raise fire alarmDetermine location of fire/explosionCheck for oil/hazardous substances pollution and possibility of...

CONTINGENCY PLAN FOR PERSONNEL INJURY

0
General emergency alarm signal : Seven or more short blast followed by one long blast Emergency:- Immediate Action Required/Members of The Team PERSONNEL INJURY:- Evacuate injured person to a safe & comfortable locationAssess the condition of the injured and administer First AidIf...

CONTINGENCY PLAN FOR MAN OVERBOARD

0
General emergency alarm signal : Seven or more short blast followed by one long blast Emergency:- Immediate Action Required/Members of The Team Man Overboard:- Release Life Buoy, take avoiding action and raise emergency alarm.Revert to manual steering and reduce main engine...

FUSE

0
A fuse is a one type of low resistance resistor that acts as a sacrificial device to provide over current protection of either the load or source circuit. Its important component is a metal wire...

TYPES OF BOILER BURNERS

0
Pressure Jet Burner: This uses the pressure of the fuel oil to create atomization and a rotating spray. The fuel at the correct viscosity, flow through the centre passage of the burner, so the...

STATIC ELECTRICITY

0
Static electricity is an variation of electric charge within or on the surface of a material. The charge remaining until it is able to move away by means of an electric current or electrical...

TRANSFORMER

0
Transformer is an electrical instrument that can transfers the electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltage of a alternating current in...

TROUBLESHOOTING OF PUMPS

0
1.Failure to build up pressure Causes: Loss of suction / air ingressDischarge valve stuck in closed positionMotor inoperationalInternal damage due to wear & tear Remedial Actions: Identify cause & rectify same 2. Vibration Causes: It is because of bearing damageMisalignment to couplingDamage to...

TROUBLESHOOTINGS FOR AUXILIARY BOILER

0
1.Auxiliary boiler feed water pump breaker faulty Causes: Breaker is tripping. It is not holding at ON position. Remedial Actions: Operate the system with the standby pump. Isolate the faulty breaker & change with new one. 2. Auxiliary boiler feed water pump...

TROUBLE SHOOTING FOR STEERING SYSTEM

0
1. Oil consumption High Causes: Low level alarm is triggered due to oil leakage.May result in system being isolated if low low alarm is trigerred. Remedial Actions: Rectify the leakage at the earliest.Isolate the system if leakage is very...