SHIPBOARD SAFETIES IN BRIEF
ENGINE ROOM CRANE BRAKE SAFETIES
Measure distance between magnet & armature, clearance should be 0.5 mm around the armature (Refer manual for exact...
CRANKCASE EXPLOSIONS
Under the normal conditions the atmosphere in the crankcase when the engine is running contains a large amount of the relatively large oil droplets of size (200...
QUESTION BANK MARINE ELECTRICAL TECHNOLOGY PART-4
Q a) Explain why it is necessary to have reverse power protection for alternators intended for Operation.
b) i. Sketch a reverse power trip.
MAIN SWITCH BOARD (MSB) SAFETIES
MSB to be installed on the raised platform.
The location where the MSB is installed should have good ventilation, illumination & affected by minimum...
NEGATIVE PHASE SEQUENCE RELAY
Negative Sequence Relay:
Negative sequence relay is used to protect the alternator or generator from the unbalance loading & negative sequence component. The...
LATEST ELECTRICAL TECHNOLOGY MMD ORAL Q & A PART-8
(a) With reference to water level control system, with the aid of sketches, how remote control of boiler water is achieved?
(b)...
LATEST ELECTRICAL TECHNOLOGY MMD ORAL Q & A PART-7
(a) Pneumatic lock up and fail safe system
Pneumatic lock up and fail safe system serve to bring about particular valve position in...
LATEST ELECTRICAL TECHNOLOGY MMD ORAL Q & A PART-6
(a) Explain about BJT (Bipolar Junction Transistor),Uni-junction transistor.
(b) Describe about NPN and PNP transistor with sketch.
(c)...
LATEST ELECTRICAL TECHNOLOGY MMD ORAL Q & A PART-5
Q Explain with the aid of sketch, the working principle of IGBT(Insulated Gate Bipolar Transistor) in varying motor speed control
LATEST ELECTRICAL TECHNOLOGY MMD ORAL Q & A PART-4
Q Explain emergency battery charging system. Show a typical wiring diagram for two batteries working on a charge-discharge
Emergency batteries charging system